no
|
code
|
name + specification
|
photo
|
|
|
Eco Thermo Floor® Silent & Warm
Panels made of wood fiber boards
|
1 |
ETF SW 001 |
supply and return panel
1000 × 500 × 30mm (0,5 m2)
pipe distance 125 mm
|
 |
PC |
|
ETF SW 009 |
1200 x 600 x 30 mm (0,72 m2)
pipe distance 150 mm
|
PC |
|
2 |
ETF SW 002 |
return panel
1000 × 248 × 30 mm (0,248 m2)
pipe distance 125 mm
|
 |
PC |
|
ETF SW 010 |
1200 x 298 x 30 mm (0,358 m2)
pipe distance 150 mm
|
PC |
|
3 |
ETF SW 011 |
supply and return panel
1200 x 600 x 30 mm (0,72 m²)
pipe distance 200 mm
|
 |
szt. |
|
4 |
ETF SW 012 |
return panel
1200 x 298 x 30 mm (0,358 m²)
pipe distance 200 mm
|
 |
szt. |
|
5 |
ETF SW 003 |
supply and return panel
1000 × 500 × 30 mm (0,5 m2)
pipe distance 250 mm
|
 |
PC |
|
ETF SW 013 |
1200 x 600 x 30 mm (0,72 m2)
pipe distance 300 mm
|
PC |
|
6 |
ETF SW 004 |
return panel
1000 × 248 × 30 mm (0,248 m2)
2 × 250 mm
|
 |
PC |
|
ETF SW 014 |
1200 x 298 x 30 mm (0,358 m2)
pipe distance 300 mm
|
PC |
|
7 |
ETF SW 005 |
supply and return single panel
1000 × 125 × 30 mm (0,125 m2)
|
 |
PC |
|
ETF SW 015 |
1000 x 248 x 30 mm (0,248 m2)
|
PC |
|
ETF SW 016 |
1200 x 148 x 30 mm (0,178 m2)
|
PC |
|
ETF SW 017 |
1200 x 198 x 30 mm (0,238 m2)
|
PC |
|
ETF SW 018 |
1200 x 298 x 30 mm (0,358 m2)
|
PC |
|
8 |
ETF SW 006 |
blank panel
1000 × 500 × 30 mm (0,5 m2)
|
 |
PC |
|
ETF SW 019 |
1200 x 600 x 30 mm (0,72 m2)
|
PC |
|
9 |
ETF SW 007 |
header panel cross over
370 x 248 x 30 mm
cross over 125 X 250 mm and vice versa
|
 |
PC |
|
10 |
ETF SW 008 |
corner panel 90º
248 x 248 x 30 mm
|
 |
PC |
|
Eco Thermo Floor® Dry Floring Elements
|
11 |
ETF DFE 501 |
supply and return panel
1200 x 600 x 18 mm
pipe distance 100 mm
(0,72 m²)
|
 |
PC |
|
12 |
ETF DFE 502 |
return panel
1200 x 600 x 18 mm
pipe distance 100 mm
(0,72 m²)
|
 |
PC |
|
13 |
ETF DFE 503 |
blank panel
1200 x 600 x 18 mm
(0,72 m²)
|
 |
PC |
|
Eco Thermo Floor® Chip Board
Panels made of chipboard MFP
|
14 |
ETF CB 201 |
supply and return panel
1200 x 600 x 22 mm
pipe distance 200 mm
|
 |
PC |
|
ETF CB 202 |
1200 x 600 x 25 mm
pipe distance 200 mm
|
PC |
|
ETF CB 203 |
1800 x 600 x 22 mm
pipe distance 200 mm
|
PC |
|
ETF CB 204 |
1800 x 600 x 25 mm
pipe distance 200 mm
|
PC |
|
ETF CB 205 |
2400 x 600 x 22 mm
pipe distance 200 mm
|
PC |
|
ETF CB 206 |
2400 x 600 x 25 mm
pipe distance 200 mm
|
PC |
|
15 |
ETF CB 207 |
return panel
1200 x 395 x 22 mm
pipe distance 200 mm
|
 |
PC |
|
ETF CB 208 |
1200 x 395 x 25 mm
pipe distance 200 mm
|
PC |
|
ETF CB 209 |
1200 x 595 x 22 mm
pipe distance 200 mm
|
PC |
|
ETF CB 210 |
1200 x 595 x 25 mm
pipe distance 200 mm
|
PC |
|
16 |
ETF CB 211 |
supply and return panel
1200 x 500 x 22 mm
pipe distance 125 mm
|
 |
PC. |
|
ETF CB 212 |
1200 x 500 x 25 mm
pipe distance 125 mm
|
PC |
|
ETF CB 213 |
1200 x 600 x 22 mm
pipe distance 150 mm
|
PC |
|
ETF CB 214 |
1200 x 600 x 25 mm
pipe distance 150 mm
|
PC |
|
ETF CB 215 |
1800 x 600 x 22 mm
pipe distance 150 mm
|
PC |
|
ETF CB 216 |
1800 x 600 x 25 mm
pipe distance 150 mm
|
PC |
|
ETF CB 217 |
2400 x 600 x 22 mm
pipe distance 150 mm
|
PC |
|
ETF CB 218 |
2400 x 600 x 25 mm
pipe distance 150 mm
|
PC |
|
17 |
ETF CB 219 |
return panel
1000 x 395 x 22 mm
pipe distance 125 mm
|
 |
PC |
|
ETF CB 220 |
1000 x 395 x 25 mm
pipe distance 125 mm
|
PC |
|
ETF CB 221 |
1000 x 595 x 22 mm
pipe distance 125 mm
|
PC |
|
ETF CB 222 |
1000 x 595 x 25 mm
pipe distance 125 mm
|
PC |
|
ETF CB 223 |
1200 x 395 x 22 mm
pipe distance 150 mm
|
PC |
|
ETF CB 224 |
1200 x 395 x 25 mm
pipe distance 150 mm
|
PC |
|
ETF CB 225 |
1200 x 595 x 22 mm
pipe distance 150 mm
|
PC |
|
ETF CB 226 |
1200 x 595 x 25 mm
pipe distance 150 mm
|
PC |
|
18 |
ETF CB 227 |
supply and return panel
1200 x 500 x 22 mm
pipe distance 250 mm
|
 |
PC |
|
ETF CB 228 |
1200 x 500 x 25 mm
pipe distance 250 mm
|
PC |
|
ETF CB 229 |
1200 x 600 x 22 mm
pipe distance 300 mm
|
PC |
|
ETF CB 230 |
1200 x 600 x 25 mm
pipe distance 300 mm
|
PC |
|
ETF CB 231 |
1800 x 600 x 22 mm
pipe distance 300 mm
|
PC |
|
ETF CB 232 |
1800 x 600 x 25 mm
pipe distance 300 mm
|
PC |
|
ETF CB 233 |
2400 x 600 x 22 mm
pipe distance 300 mm
|
PC |
|
ETF CB 234 |
2400 x 600 x 25 mm
pipe distance 300 mm
|
PC |
|
19 |
ETF CB 235 |
return panel
1000 x 395 x 22 mm
pipe distance 250 mm
|
 |
PC |
|
ETF CB 236 |
1000 x 395 x 25 mm
pipe distance 250 mm
|
PC |
|
ETF CB 237 |
1000 x 595 x 22 mm
pipe distance 250 mm
|
PC |
|
ETF CB 238 |
1000 x 595 x 25 mm
pipe distance 250 mm
|
PC |
|
ETF CB 239 |
1200 x 395 x 22 mm
pipe distance 300 mm
|
PC |
|
ETF CB 240 |
1200 x 395 x 25 mm
pipe distance 300 mm
|
PC |
|
ETF CB 241 |
1200 x 595 x 22 mm
pipe distance 300 mm
|
PC |
|
ETF CB 242 |
1200 x 595 x 25 mm
pipe distance 300 mm
|
PC |
|
20 |
ETF CB 243 |
supply and return single panel
1200 x 135 x 22 mm
|
 |
PC |
|
ETF CB 244 |
|
PC |
|
ETF CB 245 |
|
PC |
|
ETF CB 246 |
|
PC |
|
ETF CB 247 |
|
PC |
|
ETF CB 248 |
|
PC |
|
ETF CB 249 |
|
PC |
|
ETF CB 250 |
|
PC |
|
ETF CB 251 |
|
PC |
|
ETF CB 252 |
|
PC |
|
ETF CB 253 |
|
PC |
|
ETF CB 254 |
|
PC |
|
ETF CB 255 |
|
PC |
|
ETF CB 256 |
|
PC |
|
ETF CB 257 |
|
PC |
|
ETF CB 258 |
|
PC |
|
21 |
ETF CB 259 |
380 x 395 x 22 mm
|
 |
PC |
|
ETF CB 260 |
|
PC |
|
ETF CB 261 |
|
PC |
|
ETF CB 262 |
|
PC |
|
Eco Thermo Floor® Aluminium
Aluminium sheets for use directly between the joists of the floor boards renovations
recommended in particular when the joists are arranged at different spacings
|
22 |
ETF AL 116 |
Aluminium plate for 600 mm joist
spacing channels at 200 mm
500 x 600 x 0,5 mm
|
 |
PC |
|
23 |
ETF AL 117 |
Aluminium plate for 600 mm joist
spacing channels at 200 mm
500 x 400 x 0,5 mm
|
 |
PC |
|
Aluminium heat emission plates
|
24 |
ETF AL 101 |
Aluminium heat emission plate for pipes Ø 16 i 17,8 mm (without knockouts)
pipe distance 125 mm
995 x 115 x 0,5 mm
Ø 16 mm
|
 |
szt. |
|
ETF AL 102 |
pipe distance 250 mm
995 x 245 x 0,5 mm
Ø 16 mm
|
szt. |
|
ETF AL 103 |
pipe distance 150 mm
1195 x 145 x 0,5 mm
Ø 16 -17,8 mm
|
szt. |
|
ETF AL 104 |
pipe distance 200 mm
1195 x 195 x 0,5 mm
Ø 16 -17,8 mm
|
szt. |
|
ETF AL 105 |
pipe distance 300 mm
1195 x 295 x 0,5 mm
Ø 16 -17,8 mm
|
szt. |
|
25 |
ETF AL 106 |
Aluminium heat emission plate for pipes Ø 16 i 17,8 mm
pipe distance 125 mm
995 x 115 x 0,5 mm
Ø 16 mm
|
 |
szt. |
|
ETF AL 107 |
pipe distance 250 mm
995 x 245 x 0,5 mm
Ø 16 mm
|
szt. |
|
ETF AL 108 |
pipe distance 150 mm
1195 x 145 x 0,5 mm
Ø 16 -17,8 mm
|
szt. |
|
ETF AL 109 |
pipe distance 200 mm
1195 x 195 x 0,5 mm
Ø 16 -17,8 mm
|
szt. |
|
ETF AL 110 |
pipe distance 300 mm
1195 x 295 x 0,5 mm
Ø 16 -17,8 mm
|
szt. |
|
26 |
ETF AL 111 |
Aluminium heat emission plate (without knockouts)
pipe distance 125 mm
995 x 115 x 0,5 mm
|
 |
szt. |
|
ETF AL 112 |
pipe distance 150 mm
1195 x 145 x 0,5 mm
|
szt. |
|
ETF AL 113 |
pipe distance 200 mm
1195 x 195 x 0,5 mm
|
szt. |
|
ETF AL 114 |
pipe distance 250 mm
995 x 245 x 0,5 mm
|
szt. |
|
ETF AL 115 |
pipe distance 300 mm
1195 x 295 x 0,5 mm
|
szt. |
|
SUPPLEMENTAL MATERIALS SYSTEMS
|
27 |
ETF N 301 |
End mill Ø 1 6mm
|
brak zdjęcia
|
PC |
|
28 |
ETF N 302 |
End mill Ø 17,8 mm
|
brak zdjęcia
|
PC |
|
29 |
ETF MU 407 |
Foundation insulation is made of threeply corrugated board. with a thickness of 4,0 mm
for use as interlayer between aluminium
heat emission plate and laminate floors
These interlayers can be produced with
the holes shaped like the letters from
your company name
790 x 590 x 4 mm
|
 |
m2 PC |
|
30 |
ETF MU 301 |
plate UNDERFLOOR
590 × 790 × 4 mm
pack 6,9915 m2
|
 |
m2 pack |
|
ETF MU 302 |
590 × 790 x 5,5 mm
pack 6,9915 m2
|
m2 pack |
|
ETF MU 303 |
590 × 790 x 7 mm
pack 9,322 m2
|
m2 pack |
|
31 |
ETF MU 304 |
cork band
1000 × 10000 × 2 mm
|
 |
m2 roll |
|
32 |
ETF MU 405 |
plate ISOREL
2500 × 1200 × 10 mm
szt. 3 m2
|
 |
m2PC |
|
ETF MU 406 |
2500 × 1200 × 15 mm
szt. 3 m2
|
m2PC |
|